Strona 1 - Owner’s Manual

Owner’s Manual 1838 PC Programmable Multi-Door Access Controller DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310

Strona 2 - 2 1838-065-J-6-08

1.1.1 Mount Information If used to control a door or pedestrian gate, try to locate the access controller as near as possible to the entry point. The

Strona 3

1.2 Memory Chip Installation The access controller is shipped with two memory chips packaged in a separate box inside the shipping container. Th

Strona 4 - TABLE OF CONTENTS

Page 12 1838-065-J-6-08

Strona 5

SECTION 2 – WIRING Prior to installing wiring to the access control system, we suggest that you become familiar with the instructions, illustrati

Strona 6 - IMPORTANT NOTICE

2.1 WIRING GUIDELINES Do not run high voltage (115 V) power lines and communication lines in the same conduit. These should be in separate conduits

Strona 7 - IMPORTANT INFORMATION

MAIN DESCRIPTION 1 Phone Line Connection – 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire. 2 Phone Line Connection – 800 f

Strona 8 - FEATURES

2.3 WIRING DETAIL 2.3.1 Controller Only C.O.PHNElevatorControlRS 232ConnectionAuxiliary TerminalsMain TerminalRelay 04 51833, 1834, 1835, 1837, 18

Strona 9 - SECTION 1 - INSTALLATION

2.3.2 Controller & Expansion Boards 1-8 C.O.PHNElevatorControlRS 232ConnectionAuxiliary TerminalsMain TerminalRelay 04 51833, 1835, 1837, 183

Strona 10 - 10 1838-065-J-6-08

2.3.3 Controller & Expansion Boards 1-16 Main Terminal1833, 1835, 1837, 1838 CONTROLLERNOTES: Controller main terminals 15-16-17 = SYSTEM RELAY 1

Strona 11 - 1.2 Memory Chip Installation

2.3.4 Controller and 1838-120 & 121 Remote Call StationsC.O.PHNElevatorControlRS 232ConnectionMain Terminal41838 CONTROLLER123456123123 17161

Strona 12 - 12 1838-065-J-6-08

Page 2 1838-065-J-6-08

Strona 13 - SECTION 2 – WIRING

2.3.5 Controller and 1504-120 & 121 Remote Call StationsC.O.PHNElevatorControlRS 232ConnectionMain Terminal41838 CONTROLLER123456123123 171615141

Strona 14 - 2.1 WIRING GUIDELINES

2.3.6 RS-232 Cable Connection P/N 1818-0401569123456REDBLACKWHITEBROWNGREENSHIELDDOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.Detail Wiring

Strona 15 - 2.2 TERMINAL DESCRIPTIONS

2.3.7 Postal Lock Box Installation & Wiring – Optional At some locations, such as gated communities, it may be necessary to provide access to th

Strona 16 - 2.3 WIRING DETAIL

SECTION 3 – PROGRAMMING IMPORTANT! Many of the advanced features available with this access control system cannot be programmed from the system

Strona 17 - 1838-065-J-6-08 Page

3.1.2 Programming from the Keypad Follow the programming instructions as described in each section of this manual. The system will prompt you with

Strona 18 - 18 1838-065-J-6-08

3.2 PROGRAMMING WITH A PC Prior to programming the PC Programmable Telephone Entry System with the DoorKing Remote Account Manager for Windows s

Strona 19 - 1838-120/121

3.2.4 Open Tone On or Off The following programming sequence turns the open tone (when the relays activate) either On or Off. This feature is availa

Strona 20 - 1504-120/121

3.3 GENERAL PROGRAMMING Proceed with the programming steps on the following pages only if PC programming will not be used. 3.3.1 Relay Strike

Strona 21

3.3.3 Tone Open Numbers These steps will program the tone open numbers for relays 1 and 2. You will need to enter a four-digit number (see chart bel

Strona 22 - 22 1838-065-J-6-08

3.3.5 Touch-tone / Rotary-dial This programming sequence will set the remote call station to dial out in either a touch-tone or rotary format. G

Strona 23 - SECTION 3 – PROGRAMMING

Use this manual with the following models only. Model 1838 Access Controller, REV F or Higher DoorKing, Inc. reserves the right to make cha

Strona 24 - Page 24 1838-065-J-6-08

3.4 PROGRAMMING PHONE NUMBER NOTE: These programming steps are only used when a DKS 1838-120 or 1838-121 Remote Call Station is connected to the 18

Strona 25 - 3.2 PROGRAMMING WITH A PC

3.4.3 Programming Area Code Program an area code when 10-digit or long distance calling is required. The area code will be entered as a four-digi

Strona 26 - 26 1838-065-J-6-08

3.4.5 Delete Phone Number This programming sequence is used to delete the phone number under a known directory code. 1. Press * 0 1 and enter the fo

Strona 27 - 3.3 GENERAL PROGRAMMING

The PC programmable access control system must be equipped with a MemPLUS chip to program device codes into its memory. Device codes must be fiv

Strona 28 - 28 1838-065-J-6-08

3.6 FOUR-DIGIT ENTRY CODE A DoorKing slave keypad (P/N 1814-075) is required if four-digit entry codes are going to be used to access a door or gate

Strona 29

3.7 ANTI-PASS BACK – 1833, 1835, 1837 only with APB CHIP SET The programming steps below will allow you to set up and program some basic functio

Strona 30 - 30 1838-065-J-6-08

3.8 CONTROL BOARD ADJUSTMENTS DOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.1838 Board AdjustmentsRev.Title:12/06BM1838-065-4123141312111098765

Strona 31

3.8.1 Master Code Switch 1. The master code switch is left in the off position for normal operation. Turn the master code switch on when setti

Strona 32 - 32 1838-065-J-6-08

Note: 3.8.4 and 3.8.5 are only applicable if a Remote Call Station is connected to the 1838 controller. 3.8.4 Speaker Volume, Microphone and Feedbac

Strona 33

SECTION 4 – OPERATING INSTRUCTIONS 4.1 USER INSTRUCTIONS 4.1.1 Card Access Card access is provided by card readers or automatic vehicle Identifi

Strona 34 - 3.6 FOUR-DIGIT ENTRY CODE

TABLE OF CONTENTS Preface Important Notices...

Strona 35

4.2 SYSTEM ADMINISTRATOR INSTRUCTIONS The system administrator can perform the following operations from a remote location using a touch-tone telepho

Strona 36 - 36 1838-065-J-6-08

SECTION 5 – MAINTENANCE The DoorKing 1838 access controller is essentially a maintenance free device. When the unit is properly installed, it sh

Strona 37

SYMPTON POSSIBLE SOLUTION(S) Cannot get into programming mode. Wrong master code entered. Start over. Waiting too long between pushing buttons. Ente

Strona 38 - 38 1838-065-J-6-08

SYMPTON POSSIBLE SOLUTION(S) Four-digit entry codes will not work. Forgetting to press # first. Re-program the entry code ranges (3.6.3). Entry co

Strona 39 - 4.1 USER INSTRUCTIONS

5.1.2 Floor, Elevator, Security Level Test Programming This programming sequence is included for troubleshooting the elevator control board(s) only.

Strona 40 - 40 1838-065-J-6-08

5.1.4 Elevator Board / Floor Hardware Test This testing sequence will allow you to check activation of individual relays on the elevator control

Strona 41 - SECTION 5 – MAINTENANCE

5.2 ACCESSORIES Card Readers A variety of DKS, AWID and HID proximity readers are available for use with the 1838 controller. Most 26-bit card rea

Strona 42 - SYMPTON POSSIBLE SOLUTION(S)

5.3 LOG TABLES Complete the information in the tables on the following pages to maintain a record of the information that has been programmed int

Strona 43

NAME PHONE NUMBER DIR CODE ENT CODE DEVICE CODE SEC LEVEL FL ER

Strona 44 - 44 1838-065-J-6-08

1838-065-J-6-08 Page 49

Strona 45

3.5 Device Codes 3.5.1 Programming Device Codes ...

Strona 46 - 5.2 ACCESSORIES

IMPORTANT NOTICE FCC - UNITED STATES This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Par

Strona 47 - 5.3 LOG TABLES

IMPORTANT INFORMATION • Prior to beginning the installation of the access control system, we suggest that you become familiar with the instructi

Strona 48 - Page 48 1838-065-J-6-08

FEATURES • Can provide service for up to 3000 system users. • Can store up to 8000 card, transmitter or digital PIN codes. • Can interface with DK

Strona 49

SECTION 1 - INSTALLATION If you are going to use a telephone line with this controller, order it at least two weeks prior to the planned installa