Model 2351 System Expansion Boards DoorKing, Inc.120 Glasgow AvenueInglewood, California 90301U.S.A.Phone: 310-645-0023Fax: 310-641-1586www.doorkin

Strona 2

1 2 3 4 5 6 7 8NO NC NO NC NO NCDOORKING2351-010123456789101112131415161718P2POWER1234567891011121314P1OUTPUT RELAYALARM RELAYMONITOR RELAYP

Strona 3

1.3 Monitor and Alarm Relay Operation The Tracker board provides relay contacts for monitoring and alarm purposes. There are two different modes in w

Strona 4

1.3.2 Mode-2 In MODE-2 (switch 1 ON), the monitor relay is typically connected to a local alarm (bell, buzzer, light, etc.) and the alarm relay is typ

Strona 5 - TABLE OF CONTENTS

SWITCHES MONITOR RELAY ALARM RELAY 3 4 Forced Condition Proper Condition Forced Condition Proper Condition A OFF OFF Activates whenever

Strona 6

1.4 Hold Open Features There are two hold open features associated with the Tracker expansion boards: hold open time zones and an override hold open

Strona 7 - Section 1 – Setup

1.5 Board and Relay Identification When using two or more Tracker boards connected to a single access system, the board jumpers on each tracker boar

Strona 8 - 1.2.5 Reset Alarm Input

1.5.2 Relay Identification The models 1803PC, 1815, 1817, 1833, 1835 and 1837 telephone entry systems each have three relays (Relay 0, 1, and 2) on th

Strona 9 - 1.2.9 Weigand Output

Board 9System Relay 11Board 10System Relay 12Board 16System Relay 18Board 15System Relay 17Board 14System Relay 16Board 13System Relay 15Board 12

Strona 10 - 2351-010 Board Settings

Board 9System Relay 11Board 10System Relay 12Board 16System Relay 18Board 15System Relay 17Board 14System Relay 16Board 13System Relay 15Board 12Syste

Strona 11 - 1.3.1 Mode-1

1.5.3 Terminal Identification TERMINAL P1 1 Monitor Relay 2 Monitor Relay 3 Alarm Relay 4 Alarm Relay 5 Output Relay 6 Output Relay 7 Wei

Strona 13

1 2 3 4 5 6 7 8NO NC NO NC NO NCDOORKING2351-010123456789101112131415161718P2POWER1234567891011121314P1Gate 1 - DATA INGate 1 - DATA BUSYGat

Strona 14 - 1.4 Hold Open Features

Section 2 - Installation The location of the tracker board(s) is dependent on the application that it is being used. Tracker boards can be installed

Strona 15 - 1.5.1 Board Identification

2.1 Single Housing • P/N 2351-080 provides a lockable, weather resistant housing for a single tracker board. 5.753.6258.754.8757.1251 3.751.25.875 DI

Strona 16 - 1.5.2 Relay Identification

2.2 Quad Housing • P/N 2351-081 provides a lockable weather resistant housing for up to four (4) tracker boards. Includes terminal strips and four (

Strona 18

Section 3 – Wiring Information Plan your wire runs before starting the installation. Use proper wire for the weigand lines, power wires, and be sure

Strona 19 - TERMINAL P2

3.1 Tracker Boards 1-8 Detail Wiring for 40 and 50 Series Boards • Maximum wire run between Tracker boards 1-8 is 500 feet total. • Do not use twi

Strona 20 - Terminal Identification

3.2 Tracker Boards 9-16 Detail Wiring for 40 Series Boards • Maximum wire run between Tracker boards 9-16 is 500 feet total. • Do not use twisted p

Strona 21 - Section 2 - Installation

3.3 Tracker Boards 1-8 Detail Wiring for 30 Series Boards • Maximum wire run between Tracker boards 1-8 is 500 feet total. • Do not use twisted pa

Strona 22 - 2.1 Single Housing

3.4 Tracker Boards 9-16 Detail Wiring for 30 Series Boards • Maximum wire run between Tracker boards 9-16 is 500 feet total. • Do not use twisted p

Strona 23 - 2.2 Quad Housing

3Use this manual with the following models only. Tracker expansion boards 2351-010 Rev E or higher. DoorKing, Inc. reserves the right to make chang

Strona 24

3.5 Block Diagram Single Door – Typical • The block diagram below shows the necessary wire runs needed when all options (gate operator data, alarm o

Strona 25 - Block Diagram

3.6 Door Control Wiring Detail - Typical • Set output relay shorting bar on the Tracker board to N.O. (Normally Open) when using fail-secure (electr

Strona 26 - Detail Wiring

3.7 Gate Operator Data • Each tracker board can report data to the access control system from two (2) DKS gate operators; a slide or swing gate oper

Strona 27

Wiring for 9310 Gate Operator Only 24V COMMON 1PARTIAL OPEN 524V RADIO PWR 3OPEN / RADIO RELAY 2 OPEN 43-BUTTON OPEN 73-BUTTON CLOSE 8REVERSE

Strona 28

3.8 General Wiring Information The wiring of the tracker board(s) is an extremely important and integral part of the overall access control system.

Strona 29

Section 4 – Trouble Shooting Before beginning any trouble shooting, check all wiring and look for any loose connections. Double check your wiring! Th

Strona 30 - BLOCK DIAGRAM - 2351 BOARD

4.2 Weigand Device Data The weigand device (card reader, RF receiver, digital, etc.) must output data in the 26-bit weigand format. The tracker board

Strona 31

4.3 Gate Operator Data Be sure that the gate operator has Gate Tracker capability. This can be determined by checking the revision letter of the cont

Strona 32 - 3.7 Gate Operator Data

Gate Operator Event (transaction) Reports The tracker interface board sends the following gate operator data to the DKS access control system. This da

Strona 35 - Section 4 – Trouble Shooting

TABLE OF CONTENTS Section 1 – Setup 1.1 General Information...

Strona 37 - 4.3 Gate Operator Data

Section 1 – Setup The model 2351 Tracker Expansion Board allows you to expand the number of entry points that the models 1803PC, 1815, 1817, 1818, 18

Strona 38

1.2 Tracker Board Input/Output Descriptions 1.2.1 Access Control Device (Weigand) Input Tracker boards can accept weigand input data from most devi

Strona 39

1.2.6 Command Relay Input The command relay input (P2, terminals 8 & 17) is connected to the relay in the access system controller that activates